The reason for insufficient air volume of Roots vacuum pump

Sep 27, 2022|

The reason for insufficient air volume of Roots vacuum pump

Roots vacuum pump in the use of failure is inevitable. Still, we need to do is to understand the cause of failure, and master the maintenance method, so as to ensure the operation of equipment better, and prolong its service life.
Roots vacuum pump air is not enough, this failure makes the pump can not give full play to its efficiency, and can not meet the process requirements.

The reason for this failure may be: the pump speed is not enough; The seal is not strict, the inlet pipe or shaft seal connection leakage; The clearance between the rotor of the pump and the rotor, the outer rotor ring, and the pump shell, the rotor end face and the end cover circumference is too large, the return flow volume becomes large, the ambient temperature or the cooling water temperature is too high.