Vacuum pump parameters: quickly understand the technical parameters table

Oct 12, 2021|

Vacuum pump parameters: quickly understand the technical parameters table

When choosing a vacuum pump, manufacturers will put the technical parameter table in an important position for our reference. A vacuum pump technical parameter table may include: pumping speed limit vacuum pumping speed starting pressure limit pressure, need to be equipped with the front stage pump maintenance pump and other information. What do these parameters mean?· Vacuum degree: The rareness of gas in a vacuum, usually expressed in Torr or Pa. · Pumping rate: m /h or L/S refers to the gas extracted from the air inlet of the vacuum pump within a certain pressure and temperature. The unit is m /S or L/S. It refers to the gas flow at the inlet of the pump · Ultimate vacuum: after the vacuum pump is fully pumped, it is stable at a certain vacuum degree, which is the ultimate vacuum of the pump. Usually, the vacuum pump needs 12 hours of gas refining, and then 12 hours of vacuum pumping. The last hour is measured every 10 minutes, and the average value of the 6 times is the ultimate vacuum value · Ho coefficient: the ratio between the actual pumping speed on the suction channel area of the vacuum pump and the theoretical pumping speed calculated according to molecular discharge · Flow conductivity: indicates the ability of the vacuum pipeline to pass through the gas. In a stable state, the flow conductivity of the pipeline is equal to the pipeline flow divided by the pressure difference between the two ends of the pipeline, in-unit L/s · Allowable amount of water vapor: unit kg/h, refers to the mass flow rate of water vapor that can be removed by the gas holding pump in continuous operation under normal working environment. · Average free path: the average distance flown by two successive collisions of gas particles in irregular thermal motion, denoted by the symbol λ · Standard atmospheric pressure: 101325 dynes per square centimeter, in Atm

Pressure or pressure: The force per unit area of a gas molecule acting on a container wall, expressed in Pa.
· Starting pressure: refers to the pressure when the pump is started without damage and is pumped.
· Front stage pressure: refers to the outlet pressure of the vacuum pump whose exhaust pressure is less than one atmosphere.
· Maximum front stage pressure: refers to the pressure exceeding the front stage that can damage the pump.
· Maximum working pressure: only the inlet pressure corresponding to the maximum pumping volume. At this pressure, the pump can operate continuously without deterioration or damage.
· Main pump: in a vacuum system, the vacuum pump is used to obtain the vacuum required to meet specific process requirements.
· Front stage pump: the vacuum pump used to maintain the critical front stage pressure in the front stage pressure region of a vacuum pump. Such as roots pump before the configuration of rotary vane pump or slide valve pump is the front pump.
· Crude pumping pump: a vacuum pump that starts pumping air at atmospheric pressure and pumps the system pressure to another vacuum pump to start working.
· Maintenance pump: in the vacuum system, the air volume is very small, so the front pump cannot be used effectively. This is equipped with a small capacity of the auxiliary pump to maintain the main pump work, the pump is called a maintenance pump. Such as diffusion pump outlet with a small rotary vane pump, is to maintain the pump.
Other general parameters such as the voltage, power, noise, and air temperature of the vacuum pump are well understood and cannot be expanded.